No search results found for:

Measurement

QUADRANT SHOWER ENCLOSURE

1. Determine the installation method:
– on the shower tray,
– without the shower tray- external dimension of the cabin on the edge of the tile/fugue,
– without the shower tray – glass line on the edge of the tile/fugue
2. Specify the front and side part of the shower enclosure
3. Enter the width of the front part of the shower enclosure (X)
4. Enter the width of the side part of the shower enclosure (Y)
5. Check the vertical walls and enter the values of deviations (the floor must be leveled)

RECTANGULAR SHOWER ENCLOSURE

1. Determine the installation method:
– on the shower tray,
– without the shower tray- external dimension of the cabin on the edge of the tile/fugue,
– without the shower tray – glass line on the edge of the tile/fugue
2. Specify the front and side part of the shower enclosure
3. Enter the width of the front part of the shower enclosure (X)
4. Enter the width of the side part of the shower enclosure (Y)
5. Check the vertical walls and enter the values of deviations (the floor must be leveled)
6. Enter the height of the shower enclosure (H).

WALL-ADJACENT SHOWER ENCLOSURE

1. Determine the installation method:
– on the shower tray,
– without the shower tray- external dimension of the cabin on the edge of the tile/fugue,
– without the shower tray – glass line on the edge of the tile/fugue.
2. Specify the front and side parts of the shower enclosure.
3. Enter the width of the front part of the shower enclosure (X).
4. Enter the width of the side part of the shower enclosure (Y).
5. Enter the width of the side part of the shower enclosure (Z).
6. Check the vertical walls and enter the values of deviations (the floor must be leveled).
7. Enter the height of the shower enclosure (H).

SHOWER DOOR

SIGNS:
X1/2/3 – the width of the niche
H – the height of the door

1. Measure the niche at three heights: on the bottom, in the middle and at the top
2. Check the vertical walls and enter the values of deviations
3. Enter the height of the product (H).

BATHTUB SCREEN

1. Check the vertical walls and enter the values of deviations
2. Enter the width of the product (X)
3. Enter the width of the bathtub (Y)
4. Enter the height of the product (H)

RECTANGULAR SHOWER ENCLOSURE ON A BATHTUB

1. Enter the width of the front part of the shower enclosure (X)
2. Enter the width of the bathtub/partition wall (Y)*
3. Enter the height of bathtub/partition wall measured from the bottom of the shower enclosure
4. Check the vertical walls and enter the values of deviations (the floor must be leveled)
5. Enter the height of the shower enclosure (H).

*ATTENTION! The shower enclosure’s wall (glass pane +profiles) mounted on the bathtub/partition wall will be smaller by approx. 23mm than the width of the bathtub/partition wall.
For constructional reasons (possibility of tiles damage) it is not recommended to mount the magnet profile on the edge of the bathtub/partition wall.

RECTANGULAR SHOWER ENCLOSURE WITH PARTITION WALL

SIGNS:
H – the height of the shower enclosure
Q – the width of the seat/partition wall
W – the height of the seat/partition wall

1. Determine the installation method:
– on the shower tray,
– without the shower tray- external dimension of the cabin on the edge of the tile/fugue,
– without the shower tray – glass line on the edge of the tile/fugue
2. Specify the front and side part of the shower enclosure
3. Enter the width of the front part of the shower enclosure (X)
4. Enter the width of the side part of the shower enclosure (Y)
5. Check the vertical walls and enter the values of deviations (the floor must be leveled)
6. Measure the width of the partition wall (Q)
7. Measure the height of the partition wall (W)
8. Enter the height of the shower enclosure (H).

ATTENTION! CUT OUT CAN BE MADE ONLY IN FIXED GLASS PANES.

RECTANGULAR SHOWER ENCLOSURE WITH SLANT

SIGNS:
H2 – the height of the shower enclosure
H – the height of the bathroom
W – the height where the slant begins
(measured from the bottom of the shower enclosure)
Z – the width of the slant in the bathroom or “α” angle value

1. Determine the installation method:
– on the shower tray,
– without the shower tray- external dimension of the cabin on the edge of the tile/fugue,
– without the shower tray – glass line on the edge of the tile/fugue
2. Specify the front and side part of the shower enclosure
3. Enter the width of the front part of the shower enclosure (X)
4. Enter the width of the side part of the shower enclosure (Y)
5. Check the vertical walls and enter the values of deviations
6. Measure the initial height of the slant (W)*
7. Enter the angle value (α) or the width of the slant in the bathroom (Z)
8. In case of entering Z dimension, enter also H dimension – the height of the bathroom*
9. Enter the height of the product (H2)*
*measured from the bottom of the shower enclosure

SHOWER DOOR WITH CUT OUT

SIGNS:
X1/2/3 – the width of the niche
H – the height of the door
Q – the width of the seat/partition wall
W – the height of the seat/partition wall

1. Measure the niche at three heights: on the bottom, in the middle and at the top
2. Check the vertical walls and enter the values of deviations
3. Measure the width of the seat/partition wall (Q)
4. Measure the height of the seat/partition wall (W)
5. Enter the height of the product (H)

ATTENTION! CUT OUT CAN BE MADE ONLY IN FIXED GLASS PANES.

SHOWER DOOR WITH SLANT

SIGNS:
X – the width of the niche
H2 – the height of the door
H – the height of the niche
W – the height where the slant begins
(measured from the bottom of the shower door)
Z – the width of the ceiling in the niche or “α” angle value

1. Measure the niche at three heights: on the bottom, in the middle and at the top
2. Check the vertical walls and enter the values of deviations
3. Measure the height where the slant begins (W)*
4. Enter the angle value (α) or the width of the ceiling in the niche (Z)
5. In case of entering Z dimension, enter also H dimension – the height of the niche*
6. Enter the height of the product (H2)*
*measured from the bottom of the shower door

ATTENTION! ONLY FIXED GLASS PANES CAN BE CUT TO FIT THE SLANT.

HOW TO MEASURE A SLOPE ANGLE?

1. Measure the slope angle with a manual or electronic protractor.

2. Bring the protractor arms carefully to the wall and ceiling, read the indications. The angle should be greater than 90 °.

3. Measure deviations from vertical wall with a slant over its entire length. How to measure deviations, check here.

4. Measure the angle between the wall and the floor using a manual or electronic protractor.

5. Check the level of the floor in the place where the glass of the shower enclosure will stand, give the value of the deviation.

HOW TO MEASURE DEVIATIONS?

1. Deviations from vertical walls are measured using a long level (of appropriate length).
2. Put the level to the wall and set the pointer so that it indicates the vertical.
3. If, after setting the indicator, the level does not stick to the wall, measure the distance between the level and the wall.
4. Enter the value of the deviation (values ​​can be both positive and negative).